  1.     SECTION 07221
  2.  
  3.     ROOF INSULATION
  4.  
  5. NOTE ** This section is based on the MI-T-R roof insulation system as manufactured by Mizell Bros. Co., located at 99 Armour Drive, NE; Atlanta, GA  30324.  Telephone:  800-328-5401 or 404-875-9361.
  6. NOTE ** 
  7. NOTE ** The system employs flexible faced glass fiber insulation, with a variety of vapor retarders.  The patented construction of the MI-T-R high performance insulation ensures high thermal efficiency in values from R-19 to R-40.  Easily installed from the top side, the system is especially designed and manufactured to fit the spaces in a particular building.  Installation requires no special tools or training.  MI-T-R even keeps purlins or bar joists exposed for subsequent installation of electrical and mechanical systems -- without compromising the integrity of the vapor retarder.
  8. NOTE ** 
  9. NOTE ** SECTION 07221 - ROOF INSULATION, Copyright 1996, The Architect's Catalog, Inc.
  10.  
  11. PART 1    GENERAL
  12.  
  13. 1.1    SECTION INCLUDES
  14. NOTE ** Delete items below not required for project.
  15.  
  16.     A.    Roof insulation and installation.
  17.  
  18.     B.    Support system and installation.
  19.  
  20. 1.2    RELATED SECTIONS
  21. NOTE ** Delete any sections below not relevant to this project; add others as required.
  22.  
  23.     A.    Section 05120 - Structural Steel.
  24.  
  25.     B.    Section 05210 - Steel Joists.
  26.  
  27.     C.    Section 07213 - Batt Insulation.
  28.  
  29.     D.    Section 07421 - Composite Metal Building Panels.
  30.  
  31.     E.    Section 07611 - Custom Sheet Metal Roofing.
  32.  
  33.     F.    Section 13121 - Pre-Engineered Buildings.
  34.  
  35. 1.3    REFERENCES
  36. NOTE ** Delete references from the list below that are not actually required by the text of the edited section.
  37.  
  38.     A.    ASTM C 236 - Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box.
  39.  
  40.     B.    ASTM C 518 - Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus.
  41.  
  42.     C.    ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials.
  43.  
  44.     D.    ASTM E 96 - Standard Test Methods for Water Vapor Transmission of Materials.
  45.  
  46.     E.    FS HH-I-558B - Insulation, Blocks, Boards, Blankets, Felts, Sleeving, (Pipe and Tube Covering), and Pipe Fitting Covering, Thermal (Mineral Fiber, Industrial Type).
  47.  
  48. 1.4    SUBMITTALS
  49.  
  50.     A.    Submit under provisions of Section 01300.
  51.  
  52.     B.    Product Data:  Manufacturer's specifications and installation instructions.
  53.  
  54.     C.    Shop Drawings:  Include layout and location of structural steel roof framing members, details and locations of support system components, and specific data about insulation, including:
  55.         1.    R value.
  56.         2.    Approximate thickness.
  57.         3.    Facing type.
  58.         4.    Roll widths.
  59.         5.    Lengths and locations.
  60.  
  61. 1.5    REGULATORY REQUIREMENTS
  62. NOTE ** If this article is retained, select one of the two following paragraphs.
  63.  
  64.     A.    Conform to requirements of local building code.
  65.  
  66.     B.    Conform to requirements of ___________________.
  67.  
  68. 1.6    DELIVERY, STORAGE, AND HANDLING
  69.  
  70.     A.    Deliver materials in manufacturer's original, unopened packaging, with identifying tags or labels intact and legible.
  71.  
  72.     B.    Coordinate scheduling for timely deliveries and prompt installation of materials.
  73.  
  74.     C.    Store insulation and support system in a dry, protected area.  If storage area is outdoors, store material off the ground and protected by a suitable waterproof cover.  If installation is delayed for an extended period, open bag ends to allow for ventilation.
  75.  
  76. 1.7    ENVIRONMENTAL REQUIREMENTS
  77.  
  78.     A.    Handle and install insulation system only under conditions and temperatures that allow the facing material to remain workable.
  79.  
  80.     B.    Coordinate insulation placement to assure that material can be covered promptly with roof panels.  Do not leave insulation exposed overnight or to inclement weather.
  81.  
  82. 1.8    WARRANTY
  83.  
  84.     A.    Provide manufacturer's standard warranty, in accordance with requirements of Section 01740 - Warranties.
  85.  
  86. PART 2    PRODUCTS
  87.  
  88. 2.1    MANUFACTURER
  89.  
  90.     A.    Products of this section are based on the MI-T-R roof insulation system as manufactured by Mizell Bros. Co., located at 99 Armour Drive N.E., Atlanta Georgia  30324.  Telephone:  404-875-9361.
  91.         1.    Substitutions are not acceptable.
  92.  
  93. 2.2    MATERIALS
  94.  
  95.     A.    Insulation:  
  96.         1.    Comply with FS HH-I-558, Form B, Type 1, Class 6.NOTE ** Select only one of the following seven options to specify insulation resistance or thickness.
  97.  
  98.         2.    Provide thermal resistance (R) of 19 and a calculated transmittance (U Value) of 0.05, as determined by ASTM C 518.
  99.         3.    Provide thermal resistance (R) of 26 and a calculated transmittance (U Value) of 0.04, as determined by ASTM C 518.NOTE ** ASTM C 236 Test Results for MI-T-R System
  100. NOTE ** 
  101. NOTE ** Standing Seam Roof Panels:            6 inch (R19) 8 inch (R26)
  102. NOTE **   Fasteners @ 24 in, w/thermal blocks      .051       .044
  103. NOTE **   Fasteners @ 24 in, w/o thermal blocks    .059       .055
  104. NOTE ** 
  105. NOTE ** Screw Down Roof Panels:
  106. NOTE **  *Fasteners @ 12 in, w/thermal blocks      .053       .043
  107. NOTE **   Fasteners @ 12 in, w/o thermal blocks    .082       .065
  108. NOTE ** 
  109. NOTE ** * Specify only as approved by building manufacturer.
  110.  
  111.         4.    Provide thermal resistance (R) of 30 and a calculated transmittance (U Value) of 0.03, as determined by ASTM C 518.
  112.         5.    Provide thermal resistance (R) of 31 and a calculated transmittance (U Value) of 0.03, as determined by ASTM C 518.
  113.         6.    Provide thermal resistance (R) of 36 and a calculated transmittance (U Value) of 0.027, as determined by ASTM C 518.
  114.         7.    Provide thermal resistance (R) of 38 and a calculated transmittance (U Value) of 0.025, as determined by ASTM C 518.NOTE ** MI-T-R PROPERTIES
  115. NOTE ** 
  116. NOTE ** Thickness        R Value        U Value (Calculated)
  117. NOTE **              Winter Summer   Non-Reflective   Reflective
  118. NOTE **                              Winter Summer  Winter Summer
  119. NOTE **    6"        20.9    19.03    .047   .050    .046   .046
  120. NOTE **    8"        27.48   25.03    .036   .039    .035   .036
  121. NOTE **    9"        31.87   29.06    .031   .034    .031   .032
  122. NOTE **   10"        32.96   30.03    .030   .033    .030   .031
  123. NOTE **   11"        38.42   35.09    .026   .028    .026   .027
  124. NOTE **   12"        39.52   36.06    .025   .027    .025   .026        
  125.  
  126.         8.    Thickness:  Approximately __ inches, providing a composite U Value of ____, determined in accordance with ASTM C 236, using 8 inch Z purlins 60 inches on center, fasteners at ___ inches on center, [with] [without] foam blocks, 45 degrees F mean temperature corrected to 15 mph wind outside, heat flow up, non-reflective facing.
  127. NOTE ** Select one of the following twelve vapor barrier options and delete the others.
  128.  
  129.         9.    Vapor Barrier:  Face one side of insulation with white vinyl reinforced polyester having a maximum perm rating of 0.02 as determined in accordance with ASTM E 96.
  130.         10.    Vapor Barrier:  Face one side of insulation with white vinyl scrim polyester, having a maximum perm rating of 0.02 as determined in accordance with ASTM E 96.
  131.         11.    Vapor Barrier:  Face one side of insulation with standard duty foil scrim kraft, having a maximum perm rating of 0.02 as determined in accordance with ASTM E 96.
  132.         12.    Vapor Barrier:  Face one side of insulation with UV stabilized white polypropylene/scrim/foil, having a maximum perm rating of 0.02 as determined in accordance with ASTM E 96.
  133.         13.    Vapor Barrier:  Face one side of insulation with heavy duty vinyl scrim foil, having a maximum perm rating of 0.02 as determined in accordance with ASTM E 96.
  134.         14.    Vapor Barrier:  Face one side of insulation with standard duty vinyl scrim foil, having a maximum perm rating of 0.02 as determined in accordance with ASTM E 96.
  135.         15.    Vapor Barrier:  Face one side of insulation with heavy duty polypropylene scrim kraft, having a maximum perm rating of 0.02 as determined in accordance with ASTM E 96.
  136.         16.    Vapor Barrier:  Face one side of insulation with standard duty polypropylene scrim kraft, having a maximum perm rating of 0.02 as determined in accordance with ASTM E 96.
  137.         17.    Vapor Barrier:  Face one side of insulation with light duty foil scrim kraft, having a maximum perm rating of 0.03 as determined in accordance with ASTM E 96.
  138.         18.    Vapor Barrier:  Face one side of insulation with white polypropylene scrim kraft, having a maximum perm rating of 0.090 as determined in accordance with ASTM E 96.
  139.         19.    Vapor Barrier:  Face one side of insulation with white vinyl reinforced vinyl, having a maximum perm rating of 0.90 as determined in accordance with ASTM E 96.
  140.         20.    Vapor Barrier:  Face one side of insulation with white vinyl, having a maximum perm rating of 1.0 as determined in accordance with ASTM E 96.
  141.         21.    Surface Burning Characteristics:  Provide assembly of facing, adhesive, and glass fiber blanket with composite flame spread rating of 25 or less and smoke developed of 50 or less, as determined in accordance with ASTM E 84.
  142.  
  143.     B.    Support System
  144.         1.    Hangers and Stirrups:  Preformed 26 gage galvanized steel, 7/8 inches wide, with prepunched holes, factory-applied white coating, and pressure-sensitive foam tape factory-applied to inside face.
  145.             a.    Depth:  4 inches for R19 insulation.
  146.             b.    Depth:  6 inches for R26 insulation.
  147.             c.    Depth:  7 inches for R30 insulation.
  148.             d.    Depth:  7 inches for R31 insulation.
  149.             e.    Depth:  7 inches for R36 insulation.
  150.             f.    Depth:  7 inches for R38 insulation.
  151.         2.    Channels:  Preformed 26 gage galvanized steel, die formed and sheared to length, with slotted hole 1 inch from each end for attachment to hangers and stirrups, and factory-applied white coating.
  152.         3.    Fasteners:  Manufacturer's standard nylon and electrostatically galvanized splice fasteners and washers.
  153.  
  154. PART 3    EXECUTION
  155.  
  156. 3.1    EXAMINATION
  157.  
  158.     A.    Verify that roof framing system is complete and ready to receive insulation system.  Do not proceed with installation until unsatisfactory conditions have been corrected.
  159.  
  160. 3.2    INSTALLATION
  161.  
  162.     A.    Install roof insulation in strict accordance with manufacturer's instructions and approved shop drawings.
  163. NOTE ** The following two paragraphs are optional and should be deleted if foam thermal blocks are not required for project.  If foam blocks are required, select appropriate paragraph and delete the other.
  164.  
  165.     B.    Install one inch thick thermal blocks of extruded polystyrene on top of glass fiber tab and between standing seam roof panel clips.
  166.  